Skip to main content
H.R. 8706In committeeEnergy

Better Energy Storage and Safety Act

Introduced May 7, 2026Origin: House

  1. Introduced

  2. In committee

    Current step
  3. Reported

    Not yet
  4. Passed House

    Not yet
  5. Passed Senate

    Not yet
  6. Resolving differences

    Not yet
  7. Sent to the president

    Not yet
  8. Signed

    Not yet
  9. Became law

    Not yet

AI-generated from the official bill text and not reviewed by a person. It may contain errors. How summaries are made

The Better Energy Storage and Safety Act would amend the Energy Act of 2020 to expand federal research, testing, and demonstration programs focused on the safety, reliability, and fire prevention of residential and grid-scale energy storage systems.

Who it affects

The bill directly applies to the Department of Energy, the National Laboratories, the National Institute of Standards and Technology, and the United States Fire Administration. It also affects researchers, developers, manufacturers, and grant recipients involved in energy storage technologies, grid-connected storage operations, and battery recycling or second-life applications.

Based on the Introduced in House text · gemini-3.8-flash

Generated October 4, 2026 · Read the official text on Congress.gov

Your Vote

1 key actions of 2: Congress.gov's major actions and roll-call votes.

  1. Introduced in House

    Recorded by: Library of Congress

Sections of law the bill's Introduced in House text would amend, repeal or add to, found in the bill's own text. US Code current through Public Law 119-142.

Explanations are AI-generated from the bill text and the current US Code and not reviewed by a person. They may contain errors; the bill's instruction and the current text are shown so you can check them. How explanations are made

  • Amends

    42 U.S.C. 17232

    Better energy storage technology

    Current law defines an "energy storage system" as any system, equipment, facility, or technology meeting certain energy storage and dispatch criteria. This bill would clarify that definition to explicitly include any components or modules that make up such a system. In the Energy Storage System Research, Development, and Deployment Program, the bill would add modules to research objectives and specify that large-scale deployment research covers residential and utility systems. It would also add objectives focused on models, diagnostic datasets, early detection methods, and preventative maintenance to prevent damage, component failure, thermal runaway, fires, and explosions. Additionally, annual evaluations of program objectives would explicitly aim to advance testing and evaluation, increase system lifetime, and improve safety alongside lowering costs. The bill would also expand the testing and validation provisions. In addition to National Laboratories, the Secretary of Energy would coordinate with the Director of the National Institute of Standards and Technology and the Administrator of the United States Fire Administration. The testing framework would be broadened to cover specified operational, grid-connected systems installed before current codes and standards, across diverse chemistries, compositions, and manufacturing methods. Testing methodologies would be expanded to cover operating failure conditions during use, operational system-level testing, stress testing to failure, automated fire suppression, and risk mitigation equipment. Finally, the bill would require the program's 10-year strategic plan to include a summary of emerging technologies that could improve the performance, durability, or safety of grid-scale energy storage, along with potential commercial barriers.

    The bill's instruction

    Subsection (a)(1) of section 3201 of the Energy Act of 2020 (42 U.S.C. 17232) is amended by inserting “(including any components or modules that comprise such a system)” after “any system”. Paragraph (2) of section 3201(b) of the Energy Act of 2020 (42 U.S.C. 17232(b)) is amended— (A) in subparagraph (A)— (i) in the matter preceding clause (i), by inserting “modules,” after “components,”; and (ii) in clause (i), by inserting “of residential and utility energy storage systems” after “deployment”; (B) in subparagraph (I), by striking “and” after the semicolon; and (C) by adding at the end the following new subparagraphs: “ (K) models, tools, and diagnostic data sets to improve the safe installation and long-term operation of energy storage systems by abating expected failure modes that could damage such a system, including— (i) component, module, or system failure; and (ii) thermal runaway and other fire and explosion risks; and (L) early detection methods and preventative maintenance techniques relating to failure modes of energy storage systems. .” Paragraph (3) of section 3201(b) of the Energy Act of 2020 (42 U.S.C. 17232(b)) is amended to read as follows: “ (3) Benchmarking, testing, and validation (A) In general In coordination with one or more National Laboratories, the Director of the National Institute of Standards and Technology, and the Administrator of the United States Fire Administration, the Secretary shall support the development, standardized testing, and validation of energy storage systems specified in subparagraph (B), including test-bed trials and field tests, by developing testing and evaluation methodologies for the following: (i) Storage technologies, controls, and power electronics for such systems under a variety of operating and failure conditions, including such conditions that occur while such a system is being utilized. (ii) Standardized and grid performance testing for energy storage systems, materials, and technologies at each stage of development and at the operational system level. (iii) Reliability, safety, degradation, and durability testing under standard and evolving duty cycles. (iv) Component, module, and integrated system level safety and degradation stress testing to failure. (v) Accelerated life testing protocols to predict estimated lifetime metrics with accuracy. (vi) Equipment, including automated fire suppression systems, and techniques for mitigating risks of such energy storage systems. (B) Energy storage systems specified The energy storage systems specified in this subparagraph are energy storage systems that satisfy the following requirements: (i) Are under the program. (ii) Are operational and connected to the grid. (iii) Were installed before the most recent codes and standards for such systems. (iv) Represent a variety of the following characteristics: (I) Chemistries. (II) Compositions. (III) Installation and manufacturing techniques. (IV) Any other characteristic the Secretary determines appropriate. .” Paragraph (4) of section 3201(b) of the Energy Act of 2020 (42 U.S.C. 17232(b)) is amended— (A) by inserting “the testing and evaluation of” after “advance”; and (B) by striking “costs and increasing the duration” and inserting “costs, increasing the lifetime, and improving the safety”. Paragraph (5)(B) of section 3201(b) of the Energy Act of 2020 (42 U.S.C. 17232(b)) is amended— (A) in clause (iii)(II)(bb), by striking “and the mission of the Department, as determined by the Secretary”; (B) in clause (iv)(II), by striking “and” after the semicolon; (C) in clause (v), by striking the period at the end and inserting “; and”; and (D) by adding at the end the following new clause: “ (vi) include a summary of the status of any innovative, emerging, or alternative technologies that could improve the performance, durability, or safety of grid-scale energy storage systems and any potential commercial barriers to such innovative, emerging, or alternative technologies. .”

Explained by gemini-3.8-flash on November 11, 2026, against the US Code through Public Law 119-138.